Mini Ms-35 Switching Power Supply
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Zhejiang
-
Validity to:
Long-term effective
-
Last update:
2017-07-11 03:39
-
Browse the number:
193
+
Zhejiang Hongyin Electric Co., Ltd.
- Contactaixin:
Miss Lina(Mr.)
- Email: telephone:
-
Arrea:
Zhejiang
Address:1801 First Building, Huaxin Building, Chezhan Road, Liushi, Yueqing, Wenzhou, Zhejiang, China
- Website:
+
Features:
High efficiency, high reliability, low cost
AC input range selected by switch
100% full load burn-in test
Protections: Short circuit / Over load
Fixed switching frequency at 25KHz
Cooling by free air convection
2 year warranty
35W Single Output Switching Power Supply MS-35 series
Low price and high reliability
105ºC output capacitor
AC input power suitable for the world
Hight efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
Compact size,light weight
100% full-load burning test
Installed with EMI filter, minimum wave
SPECIFICATIONS | |||
OUTPUT |
|
||
Model |
MS-35-5 |
MS-35-12 |
MS-35-24 |
DC Voltage |
5V |
12V |
24V |
Rated Current |
3A |
1.3A |
0.7A |
Current Range |
0-3A |
0-1.3A |
0-0.7A |
Rated Power |
15W |
15.6W |
16.8W |
Ripple & Noise |
50mVp-p |
50mVp-p |
100mVp-p |
Voltage Adj. Range |
+10,-5% |
±10% |
±10% |
Voltage Tolerance |
±2% |
±1% |
±1% |
Inlet Stability |
±0.5% |
±0.5% |
±0.5% |
Load Stability |
±1% |
±0.5% |
±0.5% |
Setup, Rise, Hold Up Time |
200s,100ms,30ms at full load |
||
|
|
||
INPUT |
|
||
Voltage Range |
100~240VAC 47-63Hz; 240~370VDC |
||
AC Current |
0.5A/115V 0.25A/230V |
||
Efficiency |
65% |
68% |
72% |
Inrush Current |
Cold-start current 15A/115V 30A/230V |
||
Leakage Current |
<0.5mA/240VAC |
||
|
|
||
PROTECTION |
|
||
Over Load |
105%~150% |
||
Protection type: Fold back current limiting Reset: auto recovery | |||
|
|
||
ENVIRONMENT |
|
||
Working Temp., Humidity |
-10ºC~+60ºC(Refer to output derating curve), 20%~90%RH |
||
Storage Temp., Humidity |
-20ºC~+85ºC,10%~95%RH |
||
Temp. Coefficient |
±0.02%/ºC(0~50%) |
||
Vibration |
10~500Hz,2G 10min,/1cycle,Period for 60min,each axes |
||
|
|
||
SAFETY |
|
||
Withstand Voltage |
I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
||
|
|
||
STANDARD |
|
||
Safety Standard |
Meet UL1012 requirement(Not apply for the mark) |
||
EMC Standard |
Meet FCC PART15 J Conduction class B |
||
|
|
||
OTHERS |
|
||
Dimension |
85*58*38mm(L*W*H) |
||
Weight |
0.4Kg |
||
|
|
||
NOTE |
|
||
1.The testing condition for the parameter above is: 230VAC input, rated load, 25ºC 70% RH.Humidity. 2.Error.include the setting error,line stability and load stability. 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. |